Home
Overview
Download
Buy Now
Licensing
Using

 

AuditLogin

 

 

 

 

 

 

Get a Free 30 Day Evaluation of Kanaka for Mac!

 

 

Troubleshooting AuditLogin

For the most up to date issues please visit the AuditLogin Support Forum.

If you have an issue with the product and do not see it addressed here or on the forum, please send a message to support or post a question on the forum. Technical support is initiated with email and is used as the primary medium of communication. Every problem is different. If we can answer your question quickly with a reply email, that is what will occur. Sometimes we may feel that a telephone conversation may be in order for the sake of clarity and expediency. Either way, we will be back with you quickly.

Version 3.2

  • FIX: Timing-related Semaphore Abend in the AuditLogin NLM.
If the server running AUDITLGN does not hold a NDS replica of it's own server object, it must make an unlicensed connection to a remote server that does hold a replica. If this connection is lost (ex: router problem), the connection is redriven to another server. During this reconnection, if a login or logout event occured during this reconnection period, the semaphore abend would occur. This abend has been remedied by the AUDITLGN.NLM V3.23 release (May 11, 2001).
  • FIX: AUTOEXEC.NCF update does not ensure that the new LOAD command is on a new line.

This problem has been remedied by the AuditAdm.EXE V3.23 release (May 11, 2001).

  • FIX: Memory consumption in AUDITLGN.NLM.
AUDITLGN.NLM failed to free memory in certain circumstances related to timing, Client32 version, and replica location. This problem has been remedied by the AUDITLGN.NLM V3.23 release (May 11, 2001).
  • FIX: Report Header problem.
A report type of "Session Length" would result in a problem with the report header. This problem has been remedied by the CONSLDAT.NLM V3.23 release (May 11, 2001).
  • ENHANCEMENT: AuditLogin logs NDS "Workstation Object" logins and logouts. Customers have asked to ignore those transactions.
This change has been made with the AUDITLGN.NLM V3.23 release (May 11, 2001).

 